MENU ITEM DETAILS Cont'd

132 FIX 3.5MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 80 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 500 kHz


133 FIX 5.0MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 60 meter amateur band.
Available Values: 5250 ~ 5499 kHz (1 kHz steps)
Default Setting: 5250 kHz


134 FIX 5.0MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 60 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 200 kHz


135 FIX 7.0MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 40 meter amateur band.
Available Values: 7000 ~ 7299 kHz (1 kHz steps)
Default Setting: 7000 kHz


136 FIX 7.0MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 40 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 500 kHz


137 FIX 10MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 30 meter amateur band.
Available Values: 10100 ~ 10149 kHz (1 kHz steps)
Default Setting: 10100 kHz


138 FIX 10MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 30 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 50 kHz


139 FIX 14MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 20 meter amateur band.
Available Values: 14000 ~ 14349 kHz (1 kHz steps)
Default Setting: 14000 kHz


140 FIX 14MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 20 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 500 kHz


141 FIX 18MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 17 meter amateur band.
Available Values: 18000 ~ 18199 kHz (1 kHz steps)
Default Setting: 18068 kHz


142 FIX 18MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 17 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 100 kHz


143 FIX 21MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 15 meter amateur band.
Available Values: 21000 ~ 21449 kHz (1 kHz steps)
Default Setting: 21000 kHz


144 FIX 21MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 15 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 500 kHz


145 FIX 24MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 12 meter amateur band.
Available Values: 24800 ~ 24989 kHz (1 kHz steps)
Default Setting: 24890 kHz


146 FIX 24MHz SPAN
Function: Selects the desired frequency span of the FIX mode Spectrum Scope while monitoring on the 12 meter amateur band.
Available Values: 20, 50, 100, 200, 500 or 1000 kHz
Default Setting: 100 kHz


147 FIX 28MHz
Function: Selects the scan start frequency of the FIX mode Spectrum Scope while monitoring on the 10 meter amateur band.
Available Values: 28000 ~ 29699 kHz (1 kHz steps)
Default Setting: 28000 kHz